The first parameter for most of the API functions is the card_num. This is actually a channel id rather than a card...
The API initialization functions, BusTools_API_InitExtended or BusTools_API_OpenChannel, perform a memory test as part...
Share
The IRIG-B input impedance on the QPMC-1553 is 27K Ohms.
Share
The CEI-420's discrete input voltage range is +/- 100 volts. The input voltage referred to in the CEI-x20 User's Manual...
Share
Currently, the PA-100 is supported only by the following Windows operating systems: 3.x, 9x, and NT. Windows 3.x support...
Share
The IRIG TIME CODE standard [IRIG STANDARD 200-98, Range Commander's Council, InterRange Instrumentation Group] details...
Share
This usually occurs when a Condor board is installed before the API in a Windows system with Plug-and-Play. Windows...
Share
Test Config is located in at c:\Program Files\Condor Engineering\examples\c\win32\tstcfg.bat. The "Test Config"...
Share
The 573/717 receiver receives signals with a baud rate within +/- 20% of the programmed baud rate.
Share
The IP-D1553 channel 1 pin-out is identical to the IP-1553, assuming the connections are transformer [long stub] coupled...