The specific errors are as follows: Board Failed Initialization Board Number: 2 Error Status: 50 OR WinRT not loaded for...
To clarify the symptoms: Changing the order of the cards in the PCI slots causes the same error. No matter which card...
Share
CEI620 and CEI600 are +5V PCI signaling only.
Share
Yes, the data is transmitted externally on the bus.
Share
Per the ARINC 429 specification, a compliant ARINC 429 driver can drive at least 20 compliant loads.
Share
Since Windows NT is not a full real-time system, there are things taking place below the surface. This obviously...
Share
To properly run the internal self test for all supported hardware, start with a clean file configuration (create a new...
Share
Scheduled transmissions are not adversely affected by calling AR_MODIFY_MSG at a higher frequency than the transmission...
Share
Once you've defined a message using AR_DEFINE_MSG, the unique message ID returned remains valid until AR_INIT_DUAL_PORT...
Share
The PA-100 needs a minimum time delay of 100ms between the time the PA-100 command to change the baud rate is sent and...