VMIVME-3113A with Channel 0 in IIOC Systems

Intermittent errors on VMIVME-3113A channel zero when using an IIOC 90xx system.

If you are using the 3113A in Intelligent IO Controller (IIOC) systems, intermittent errors on Channel 0 are probably due to the self-test voltage being switched into channel zero when the controller performs the online back ground test. For this reason, we recommend you consider this if you use channel zero’s input. You can confirm that this is the problem in your system by going into the debug menu and setting the back ground interval from the default 60,000mS to 0mS. This will cause channel 0 to be used continuously for background testing.